LA FITNESS CENTER (INDOOR POOL)

2880 N DRUID HILLS ROAD, NE NE ATLANTA, GA 30329

Pool
Latest score
90
Jun 20, 2025
City
North Druid Hills
County
DeKalb
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 20, 2025

Permit/Opening

Score: 903 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): An adequately sized flow meter shall be installed.

Observation: Couldn't get a reading on second flow meter because indicator was above max value. The max value should be 270. Max value observed to be 140.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Permanent, slip-resistant, easily- readable depth markers shall be indicated in feet and inches.

Observation: The depth marker between the handrails read "4 1/2". It needs to state 4 ft 6 in. Markers on the waterline read "3 1/2 ft". It should state 3ft 6in.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): Each bathroom shall have a diaper changing table/station.

Observation: No diaper changing table/station. Diaper changing table found only in the womens side of the "stretch room".

Jun 17, 2025

Permit/Opening

Score: 793 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(3): When pool is not open for use, access to the pool area shall be secured/prohibited by the closing & securing of all entry points.

Observation: The gate self closes, but it does NOT self-latch or self-lock.

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7): An adequately sized flow meter shall indicate the circulation rate.

Observation: Flow meter indicator is stuck. Couldn't get a flow meter reading.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): Each bathroom shall have a diaper changing table/station.

Observation: No diaper changing table/station.

Jul 30, 2024

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a twenty-four hour basis to obtain the minimum required number of one turnover every six hours.
Turnover rate is below the minimum of 180

Jun 26, 2023

Routine

Score: 943 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

3-188(d)(1) Depth markers on pool deck and inside pool wall must be in feet and inches. Observed 1/2 feet markers.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

13-187(c) the current inspection report shall be displayed in a conspicuous place where it is easily readable by the public at all times upon entry into the pool area. Observed the most recent inspection report not posted.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Per DeKalb County pool code 13-202(i), Each pool facility shall have in place a departmentally approve Emergency Action Plan (EAP). A written copy of the EAP shall be located to allow for immediate access in case of emergency. The EAP shall include a "Chemical Emergency Evacuation Plan," an "Emergency Crisis Plan," a "Water Rescue and Injury Emergency Plan," a "Drill Procedure for Emergency Situations," and other plans and safety programs.

Observed no EAP in place, gave template to manager