Stonecrest, DeKalb County

WESLEY KENSINGTON APTS. (POOL 1 UPR)

100 KENSINGTON CIR LITHONIA, GA 30038

Pool
Latest score
74
May 13, 2026
City
Stonecrest
County
DeKalb
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 13, 2026

Permit/Opening

Score: 747 violations

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d): Pool shall be provided with a coast guard approved lifesaving ring firmly attached to rope handles and a throwing rope with a diameter of 1/4”-3/8”. Observed life ring rope handle broken.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a): The equipment shall be operated continuously to obtain the minimum required turnover of one turnover every 4 hours. The minimum required flow meter reading to achieve the required turnover is 120 on each flow meter (2). Observed a flow meter reading of 50 on each flow meter.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

13-188(d)(1): Permanent, slip resistant depth markers at least 4 inches high in black letters and numbers on a white background indicated in feet and inches arranged uniformly on all sides of the pool are required. Observed depth markers not marked in feet and inches (4 1/2 ft).

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(k): A minimum of 1 diaper changing station for babies shall be provided in each women’s and men’s bathroom. Observed no diaper changing station in either bathroom. No IHH at this time.

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

13-201(c)(3): 1 lavatory with tempered water between 70F-104F shall be provided for each 100 women or men. Observed no hot water in the women’s bathroom.

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: No

13-198(a): The entry door to the equipment room shall be kept locked except for the pool servicing equipment. Observed no lock on the equipment room door. COS.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5): Pool shall be kept free from sediment, dirt and debris. Observed assortment of small rocks/ broken concrete pieces in the pool.

Aug 22, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 17, 2025

Routine

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a twenty four hour basis to obtain the minimum required number of four turnovers per day, or one turnover every six hours. Flow meter did not meet these standards.

May 15, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 27, 2024

Routine

Score: 802 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189 (c)(1) The pool shall maintained alkaline condition with pH level between 7.2 to 7.8. The pH was observed at 8.0 and corrected to 7.2.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously to obtain minimum turnover of 6 hours. The rate was at 50 gpm.

May 24, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 27, 2023

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(a)(5) All pools shall be kept from sediment, dirt, or debris by frequent brushing. Visible scum shall be removed. I observed sediment and leaves at the bottom of the pool.

May 25, 2023

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pool chemicals stored on the floor.