Stonecrest, DeKalb County

LA FITNESS (POOL)

6088 COVINGTON HWY DECATUR, GA 30035

Pool
Latest score
100
Mar 25, 2026
City
Stonecrest
County
DeKalb
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 25, 2026

Routine

Score: 1000 violations
No violations recorded for this inspection.

Nov 21, 2025

Routine

Score: 942 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: Yes

Flow meter not working at time of inspection.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed door open and unlocked for the chlorine. Advised to keep door locked at all times

Sep 17, 2025

Re-inspection

Score: 951 violation

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Flow meter not operational, at time of inspection.

Sep 9, 2025

Routine

Score: 755 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free Cl reading 1.99ppm

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH reading- 6.8ppm

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

Flow meter not operational, at time of inspection.

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

CPO certificate not available at time of inspection.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed chemicals stored of the floor in pool room

Mar 17, 2025

Routine

Score: 943 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Observed the flow meter not working properly Corrective Action: 13-190(a) - The equipment shall be operated continuously on a twenty-four(24) hour basis to obtain the minimum required number of four (4) turnovers per day, or one turnover every six (6) hours (pools), every 30 mins for spa. Advised to have repaired.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pool surface with debris build and visible scum on the bottom surface area. Corrective Action: 13-189(a)(5)All pools shall be kept free from sediment, dirt or debris by frequent brushing and vacuuming of the bottom and sidewall Visible scum shall be removed immediately. Advised PIC pool shall be drain and deep cleaned given 30 days.

37 - other violations of the chapter

1 ptsCorrected: YesRepeat: No

Observed chemical door open upon entering pool area. Corrective Action: 13-198(a)- The entry door shall open to the exterior of the equipment room or enclosure and shall be kept locked except for pool servicing. Corrected onsite: door was closed and locked.

Oct 4, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 21, 2024

Routine

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed chemicals stored directly on floor. Advised to remove chemicals from floor.

Mar 6, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Feb 21, 2024

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone not working. COS- pool was closed and door was locked. Advised to have phone repaired. 13-202(g) - An operable hard-wired, weatherproof telephone with direct 911 access or capability installed in a conspicuous location shall be readily available at all times within the pool enclosure

May 31, 2023

Routine

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed handrails in disrepair advised to have repaired.