Jun 12, 2026
Re-inspection
3535 LAWRENCEVILLE HWY TUCKER, GA 30084
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Routine
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Free chlorine must be maintained between 3ppm and 10ppm. The chlorine reading was 0.25ppm
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH must be maintained between 7.2 and 7.8, the pH was 7.1.
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
I could not locate the daily recordkeeping log.
CPO's number must be displayed and posted.
Permit/Opening
Permit/Opening
13-202(a)(1): The barrier shall not have any openings wherein a sphere, 4” in diameter is able to be passed through any portion of the barrier. Maximum chain link fence mesh opening is 1¼” Observed hole over 4 inches in chain link fence. Advised to repair.
13-196(a)(4): Each skimmer shall have a properly designed and operating weir or other departmentally approved means of providing effective skimming. Observed 1 skimmer missing a weir.
13-189(c)(2): Cyanuric acid levels shall not exceed 100ppm Observed cyanuric acid levels at 166+ppm.
13-188(h)(3): Pool deck shall be maintained in good repair. Observed large cracks in pool deck surface.
13-201(k): At all times a supply of liquid soap, toilet paper and paper towels shall be provided and accessible to users. Observed no paper towels or toliet paper in restroom.
13-188(h)(9): A minimum of 1 covered and lined trash receptacle shall be provided and placed in a convenient location in the pool area.
Permit/Opening
Permit/Opening
The emergency phone audio was not working.
Bobber still missing. Advised on replacing flow meter.
Routine
13-190(a): The equipment shall be operated continuously on a 24-hour basis to maintain a minimum of 4 turnovers per day. Observed flow meter with a reading of 40 gpm, should be at least 55 gpm.
13-189(a): All pools shall be kept free from sediment, dirt or debris by frequently brushing and vacuuming of the bottom and sidewalls. Observed excessive staining on the bottom and sidewalls of the pool.
Re-inspection
13-190(a): The equipment shall be operated continuously on a 24-hour basis to maintain a minimum of 4 turnovers per day. Observed flow meter with a reading of 0, should be at least 56.
13-189(a): All pools shall be kept free from sediment, dirt or debris by frequently brushing and vacuuming of the bottom and sidewalls. Observed excessive staining on the bottom and sidewalls of the pool.
Routine
13-190(a): Each pool shall be provided with 2 or more main drain openings. Observation: could not see main drains in the bottom of the pool.
13-189(c)(6) - At all times the water shall be of such clarity that the main drains are clearly visible from the deck. Observation: pool water was cloudy, could not see bottom of the pool.
13-189(c)(1) Free chlorine shall be maintained between 3ppm and 10ppm. Observed chlorine was 0.12 and again at 0.28.
N/A- COULD NOT ACCESS EQUIPMENT ROOM
N/A- COULD NOT ACCESS EQUIPMENT ROOM
N/A- COULD NOT ACCESS EQUIPMENT ROOM
13-202(1): Tightly stretched float line shall be installed across the pool along slope-break in pool where depths exceed 5'. Observed float line present in pool but broken and not secure.
13-190(a) All circulation system components shall function properly. Observed inoperable skimmers not properly maintained, needs to be cleaned of dirt, debris, and leaves.
13-189(a): Water supplied to the pool is readily accessible for inspection, repair or testing. Observation: pool water level is too low, skimmers can not operate properly.
Permit/Opening
13-190(a)(7): An adequately sized flow meter shall be installed on the return line to accurately indicate the circulation rate in gallons per minute (GPM); shall be conspicuously located. Observed bobber inside of flow meter missing. Advised to replace.
Re-inspection
13-189(c)(4) Pool shall be tested for disinfectant level at least 2 times each day. Pool log showed that it was not being tested daily
13-201(k) At all times a supply of liquid soap, toilet paper and paper towels shall be provided and accessible to users. Observed bathroom with no liquid soap
13-202(k) - each pool shall be supplied with a readily available first aid kit equipped to treat at least 15 people. Observed first aid kit needs restocking
Routine
13-189(c)(1) Free chlorine shall be maintained between 3ppm and 10ppm. Observed chlorine was 0.14
13-202(D) - lifesaving ring should be firmly attached to a throwing rope. Observed no rope on ring
13-189(c)(4) Pool shall be tested for disinfectant level at least 2 times each day. Pool log showed that it was not being tested daily
13-190(a) All circulation system components shall function properly. Observed inoperable skimmers
13-201(k) At all times a supply of liquid soap, toilet paper and paper towels shall be provided and accessible to users. Observed bathroom with no liquid soap or paper towels
13-202(k) - each pool shall be supplied with a readily available first aid kit equipped to treat at least 15 people. Observed first aid kit needs restocking
Re-inspection
13-187(c) - operating permit shall be framed and displayed as close to pool entrance as possible
13-202(k) - first aid kit shall be supplied to treat at least 15 people
Routine
13-189(c)(6) - water shall be of such clarity that the main drains are clearly visible from the deck.
13-190(a) - equipment shall operate continuously on a 24-hour basis to obtain minimum required one turnover every 6 hours. Flowmeter was not operable
13-189(c)(4) Pool shall be tested for disinfectant level at least 2 times each day. Pool log showed that it was not being tested daily
13-190(a) All circulation system components shall function properly. At the time of inspection, skimmers were not on.
13-201(k) At all times a supply of liquid soap, toilet paper and paper towels shall be provided and accessible to users. Observed bathroom with no toilet paper or paper towels
13-187(c) - Current inspection report shall be displayed
13-196(a) - water level shall be maintained within operation water level range of the system's skimmer weir device. Water level should reach half the height of the skimmers.
13-202(K) - Each Pool shall be supplied with a readily available test kit. Observed test kit needed to be restocked.
Routine
13-189(c)(1) Free chlorine shall be maintained between 3ppm and 10ppm. Chlorine was 0.16ppm and corrected to 5.41
13-189(c)(4) Pool shall be tested for disinfectant level at least 2 times each day. Pool log showed that it was not being tested daily
13-190(a) All circulation system components shall function properly. At the time of inspection, skimmers were not on. Corrected on site
13-201(k) A supply of liquid soap shall be provided in bathhouse. Bathroom did not have any soap.