Douglasville, Douglas County

RESERVE AT DOUGLASVILLE

7755 DALLAS HWY DOUGLASVILLE, GA 30134

Pool
Latest score
78
Sep 11, 2025
City
Douglasville
County
Douglas
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Sep 11, 2025

Routine

Score: 788 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed left gate is not self-closing. Gate must be maintained self-closing

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine at 0ppm. CA: Must be maintained between 2-10ppm

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

Observed pH at 7.0. CA: Must be maintained between 7.2 - 7.8

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(1) - (1) disinfectant equipment and chemical feeders, such as flow-through chemical feeders, electrolytic chemical generators, mechanical chemical feeders, chemical feed pumps, and automated controllers shall comply with the requirements of nsf standard 5

15 ptsCorrected: NoRepeat: No

Observed 2 chlorine tablets in each skimmer (4 skimmers total) CA: Chlorinator must be used and operating properly.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observe safety buoy missing from pool deck. Safety buoy must be replaced.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter float stuck at 0gpm.CA: Flow meter must be operating properly

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Observed restrooms missing paper towels. CA: Paper towels must be replaced

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

Observed extremely low water level-below depth markers and skimmer inlets. CA: Maintain water level halfway of depth marker tile

Jul 1, 2025

Permit/Opening

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed low water level. CA: Maintain water level halfway of depth marker tile

Aug 6, 2024

Permit/Opening

Score: 727 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed front gate (opposite of exit sign) not fully self-closing. CA: Must be maintained self-closing.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine at 0ppm. CA: Must be maintained between 2-10ppm

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH at 7.0. CA: Must be maintained between 7.2 - 7.8

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter float stuck.CA: Flow meter must be operating properly

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed chemical log not maintained. CA: Chemicals must be self-inspected log must be maintained.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: Yes

Observed pool risk sign missing rules 1-5. CA: Full pool sign must be posted.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Mens restroom missing toilet paper and paper towels. CA: Must be maintained.

Aug 10, 2023

Re-inspection

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Peak occupancy sign must be larger. CA: obtain proper size sign.

Jul 7, 2023

Permit/Opening

Score: 796 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed that the main gate did not self-close. CA: Discussed repairing self-closer.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed that the emergency phone was not working. CA: Discussed that the emergency phone must be operational.

Observed chlorine tablets in skimmer. COS: Tablets removed.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: YesRepeat: No

Observed tablets in skimmer. COS: Tablets removed.

23 - automated controller operational; pumps interlocked

Regulation: 511-3-5-.16(3)(c ) - (c) chemical feed pumps and controllers shall be wired so they cannot operate unless the filter pump is running. if the chlorinator has an independent timer, the filter and chemical feed pump timers shall be interlocked.

5 ptsCorrected: NoRepeat: No

Observed that the chemical feeder was not wired to the pump so it will turn off when the pump does. CA: Discussed that the feed must turn off with the pump.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Hose bib lacks back flow protector. CA: install back flow protector.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed that the replacement cartridge fillers are needed. CA: Obtain replacement filters.