Douglasville, Douglas County

NOVO SWEETWATER

1521 LEE RD LITHIA SPRINGS, GA 30122

Pool
Latest score
94
Nov 4, 2025
City
Douglasville
County
Douglas
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Nov 4, 2025

Re-inspection

Score: 942 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

OBSERVED CYA ABOVE 90PPM. CA: MAINTAIN LEVELS.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED MISSING BOOT CAPS ON LADDERS. CA: REPLACE BOOT CAPS.

Oct 16, 2025

Re-inspection

Score: 793 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

OBSERVED CL ABOVE 10PPM. CA: MAINTAIN LEVELS

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

OBSERVED CYA ABOVE 90PPM. CA: MAINTAIN LEVELS.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED MISSING BOOT CAPS ON LADDERS. CA: REPLACE BOOT CAPS.

Sep 26, 2025

Routine

Score: 832 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Cl levels 0. Maintain Cl levels.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED MISSING BOOT CAPS ON LADDERS. CA: REPLACE BOOT CAPS.

Jul 2, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 31, 2024

Re-inspection

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

OBSERVED EMERGENCY PHONE NOT BEING A LANDLINE. CA: INSTALL HARD WIRED (LANDLINE) PHONE.

May 21, 2024

Re-inspection

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone is not operable.

May 10, 2024

Permit/Opening

Score: 788 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Front gate not self-closing. CA Repair gate.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone not present. CA- Install 911 Hardwired telephone line.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Cl levels 0. Maintain Cl levels.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH observed at 8.0 Maintain between 7.2 and 7.8

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Shepards hook must be screwed on with bolt and nut.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Weirs not present. CA: Add Weirs.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Peak Occupancy sign, emergency cut off sign and phone sign not present. CA: Post signs.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(i) - (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.

1 ptsCorrected: NoRepeat: No

Rest room must be stocked observed restroom lacking supplies.