May 19, 2026

Permit/Opening

Score: 961 violation

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

OBSERVED NO TRAINING CERTIFICATE AVAILABLE ONSITE AND APPROVED CA:The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

May 12, 2026

Permit/Opening

Score: 716 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine concentration at 1 ppm. CA: Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

SKIMMERS OBSERVED WITH NO WEIRS. CA:Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

SKIMMERS OBSERVED WITH NO WEIRS. CA:Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

OBSERVED FAULTY GAUGES CA : ) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location. (a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

OBSERVED NO TRAINING CERTIFICATE AVAILABLE ONSITE AND APPROVED CA:The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

OBSERVED NO PEAK OCCUPANCY SIGN LEGIBLE INCLEAR VIEW CA: A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy

Aug 20, 2025

Routine

Score: 913 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

NO DEPTH MARKERS OBSERVED ON THE DECK. CA: BRING DEPTH MARKERS TO CODE.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

CYANURIC ACID WAS OBSERVED TO BE OVER 90

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

NO SHOWER PROVIDED CA: BRING THE STATUS TO CODE

Jul 23, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 19, 2025

Re-inspection

Score: 922 violations

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

NO DEPTH MARKERS OBSERVED ON THE DECK. CA: BRING DEPTH MARKERS TO CODE.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

SKIMMERS OBSERVED WITH NO WEIRS. CA: REPLACE WEIRS

May 6, 2025

Permit/Opening

Score: 773 violations

3 - compliant drain covers secure, present and no cracks

Regulation: .10(5) - compliant drain cover

15 ptsCorrected: NoRepeat: No

observed main drain covers broken. CA: replace main drain covers.

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: Yes

NO DEPTH MARKERS OBSERVED ON THE DECK. CA: BRING DEPTH MARKERS TO CODE.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: Yes

SKIMMERS OBSERVED WITH NO WEIRS. CA: REPLACE WEIRS

Jul 10, 2024

Permit/Opening

Score: 912 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Observed Broken Flow meter.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Pool Resurfaced without adding Deck (no diving and Depth) markers.