DOUGLASVILLE, Douglas County

TRIBUTARY @ RIVER BANKS (MAIN)

1949 LOXFORD DR DOUGLASVILLE, GA 30134

Pool
Latest score
100
May 8, 2026
City
DOUGLASVILLE
County
Douglas
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 8, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 28, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

OBSERVED CYA ABOVE 90 PPM. CA: MAINTAIN CYA.

Jul 23, 2025

Routine

Score: 767 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

OBSERVED CHLORINE ABOVE 10PPM. CA: MAINTAIN BETWEEN 2-10PPM

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WEIRS. CA: REPLACE WEIRS.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WEIRS. CA: REPLACE WEIRS.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

OBSERVED SKIMMER NEAR THE RESTROOMS BROKEN. CA: FIX SKIMMER.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

OBSERVED CYA ABOVE 90 PPM. CA: MAINTAIN CYA.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(k) - (k) fixtures shall be designed so that they may be readily and frequently cleaned and

1 ptsCorrected: NoRepeat: No

OBSERVED TOILET SEAT IN ADA STALL BROKEN IN MEN'S RESTROOM. CA: FIX TOILET.

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(e ) - (e) soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. the dispenser shall be of all metal or plastic. no glass shall be permitted in these units.

1 ptsCorrected: NoRepeat: No

OBSERVED NO SOAP WIN WOMENS RESTROOM. CA: PROVIDE SOAP.

May 15, 2025

Permit/Opening

Score: 883 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED (2) WEIRS MISSING AT 6FT END OF POOL. CA: REPLACE WEIRS.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

OBESERVED RETURN COVER NOT ATTACHED AT SHALLOW END OF POOL. CA: REPLACE COVER.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

OBSERVED CYA ABOVE 90 PPM. CA: MAINTAIN CYA.

Aug 2, 2024

Re-inspection

Score: 922 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WEIRS. CA: REPLACE WEIRS.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(a) - (a) pools shall use wall or floor inlets that are adequate in design, number and location to provide adequate mixing.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING RETURN COVER AT DEEP END OF POOL. CA: REPLACE COVER.

Aug 1, 2024

Routine

Score: 812 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

OBSERVED EMERGENCY PHONE INOPERABLE. CA: FIX EMERGENCY PHONE.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

OBSERVED MISSING WEIRS. CA: REPLACE WEIRS.

May 7, 2024

Permit/Opening

Score: 982 violations

29 - toilets & lavatories: clean, maintained, and stocked

1 ptsCorrected: NoRepeat: No

OBSERVED TOILET IN MEN'S RESTROON NOT WORKING. CA: FIX TOILET.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

OBSERVED 2 DECK SHOWERS NOT WORKING. CA: FIX DECK SHOWERS.