Lithia Springs, Douglas County

QUALITY INN & SUITES

1100 N BLAIRS BRIDGE RD AUSTELL, GA 30168

Pool
Latest score
96
May 7, 2026
City
Lithia Springs
County
Douglas
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 7, 2026

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

Observed Cyanuric Acid level above 100ppm. Informed that the acceptable range of cyanuric acid should be between 0-90ppm

Aug 19, 2025

Routine

Score: 744 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

the ph was 7.0

14 - vacuum line protected

5 ptsCorrected: NoRepeat: No

VACUUM LINE OBSERVED PLUG WITH A BOOT CAP: WAS JUST PUT WHEN ASKED ABOUT IT CA: OBTAIN A VGB APPROVED VACUUM LINE COVER

20 - return inlets maintained

4 ptsCorrected: NoRepeat: No

THE CYNARIC ACID WAS ABOVE 100 PPM CA THE MAXIMUM AMMOUNT TO BE OBSERVED AT 90 PPM

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

OBSERVED HABD RAILS NOT SECURE CA: SECURE THE HAND RAIL

May 15, 2025

Permit/Opening

Score: 884 violations

14 - vacuum line protected

Regulation: 511-3-5-.10(7) - (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.

5 ptsCorrected: NoRepeat: No

VACUUM LINE OBSERVED PLUG WITH A BOOT CAP: CA: OBTAIN A VGB APPROVED VACUUM LINE COVER

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

OBSERVED RETURN LINE COVERS ON EQUALIZER LINES. CA: INTALL VGB COMPLIANT EQUALIZER LINE COVERS

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

OBSERVED NO BOOT CAPS ON LADDER CA: INSTALL BOOT CAPS

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

OBSERVED LIGHTS NOT WORKING IN POOL. CA: REPAIR LIGHTS AND NO NIGHT SWIMMING.

ORDER NEW " NO LIFEGUARD SIGN" NO NIGHT SWIMMING LIFERINGWILL NEED REPLACEMENT

May 10, 2024

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed Cyanuric Acid level above 100ppm. Informed that the acceptable range of cyanuric acid should be between 0-90ppm

Apr 30, 2024

Permit/Opening

Score: 812 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed Chlorine levels too high. CA: Maintain proper disinfectant levels.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

Observed Cyanuric Acid level above 100ppm. Informed that the acceptable range of cyanuric acid should be between 0-90ppm