Mar 20, 2026
Permit/Opening
221 QUARTZ DR RINCON, GA 31326
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Observed disinfectant and pH not being tested twice per day.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed two of the skimmer baskets missing weirs.
Observed calcium hardness at 132 ppm, lower than the required minimum 150 ppm.
Observed total alkalinity at 32 ppm, lower than the required minimum 60 ppm.
Permit/Opening
Re-inspection
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed emergency phone incapable of making out calls. Property manager was informed, and the pool will be re-inspected when the phone is repaired.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed one of the skimmer baskets missing a weir.
Permit/Opening
Re-inspection
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Observed disinfectant and pH not being tested twice per day. Observed dry logging of chemical values (today's date at 5 pm).
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed one of the skimmer baskets missing a weir.
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
Observed the current inspection report not posted in public view.