Peachtree City, Fayette County

Somerby of Peachtree City Phase II

300 ROCKAWAY RD PEACHTREE CITY, GA 30269

Pool
Latest score
97
Feb 3, 2026
City
Peachtree City
County
Fayette
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Feb 3, 2026

Permit/Opening

Score: 972 violations

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed that the facility does not have the words, "no diving" properly marked; it is on one tile and the wording is too small. Code: The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

.13(2)(b)- Observed that the facility does not have a gas fired equipment inspection for their pool heater. CA: An annual gas-fired equipment inspection shall be conducted.

Aug 27, 2025

Routine

Score: 737 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

15 ptsCorrected: NoRepeat: No

Observed that neither entrance locks and prevents unauthorized entry; exterior door is not self closing. COS. Exterior door is locked. For interior door, facility shall have until next pool season to install a proper locking mechanism for the door. CA: Facility shall provide and maintain a barrier to prevent entry.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed that there is no available information to verify a daily safety check is being performed. CA: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed that there is no available information to verify a daily safety check is being performed. CA: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(g) - (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.

4 ptsCorrected: NoRepeat: No

Observed that the skimmer equalize lines were not protected by the float valve assembly and some of the check valves were missing. CA: Skimmer lines shall be properly protected.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Observed that the life guard signage is incorrect/incorrect height. CA: Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.13(2)(b): An annual gas fired inspection is not readily available onsite for review. An annual gas fired inspection shall be performed by a qualified professional.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.17 - Observed alkalinity of 40 PPM. CA: Alkalinity shall be between 60 and 180 PPM.

Dec 27, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 24, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jul 1, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Dec 29, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 22, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.