May 5, 2026

Permit/Opening

Score: 942 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Depth markers are not present on tile. The markers are painted on in black paint. ". Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

The words No Diving are not permanent in nature on the pool deck; painted on. There is no universal symbol for No diving present.The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Aug 18, 2025

Routine

Score: 8210 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed there are no available records onsite to verify twice daily chemical testing is performed. CA: The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be completed based on the requirements of the code.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed that there is no available information to verify a daily safety check is being performed. CA: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

Observed that the rope float was not in place. CA: A rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of seven feet or less.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed that the weirs were missing. CA: Each skimmer shall have a weir that adjusts automatically to variations in water level.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo

2 ptsCorrected: NoRepeat: No

Observed gaps larger than 3/16th of an inch in the decking. CA: Open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. Construction joints where pool coping meets the decks shall be watertight and shall not allow water to pass to the ground beneath.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Did not observe the no life guard on duty sign. CA: Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed that the pool risks was not posted. CA: The pool risks with all required verbiage and required height of letters shall be posted.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed that the peak occupancy sign did not have the number on it. CA: Peak theoretical occupancy shall be posted.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.06(3)(f) - Observed that there are stairs without handrails. CA: All stairs shall have a handrail that is installed as required by the code.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

.18(3)(i) - Observed that the depth markers on the coping of the pool were not consistent with the depth marker on the pool wall. CA: Pool depth markers shall be correct within plus or minus 3 inches at normal operating level.

Mar 14, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 19, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Mar 14, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 11, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.