May 5, 2026
Routine
241 ATLANTA RD CUMMING, GA 30040
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
Routine
Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)
High temperature dish machine not reaching sanitization temperature at plate level. Advised repair/replace/remove dish machine. COS-Use 3compartment sink to wash/rinse/and sanitize utensils.
Regulation: 511-6-1.04(4)(n)2,3,4 - gloves, use limitations, slash resistant gloves & cloth gloves (c)
Facility has not have a supply of gloves in the event a food handler has a hand injury. Advise- keep a supply of gloves on hand at all times.
Regulation: 511-6-1.05(6)(q)1&3 - good repair & calibration (c)
Walk-in condenser is leaking. Advise- repair/replace unit. Any foods that come into contact with condenser waste (non-potable water) shall be discarded.
Regulation: 511-6-1.05(3)(h),(i),(j) - temperature measuring device, manual warewashing; sanitizing solutions, testing device (pf)
Facility does not have high temperature test strips or high temperature submergible thermometer to test dish machine sanitization temperature. Advise-obtain measuring device for dish machine. 511-6-1.05(3)(h),(i),(j) - Temperature Measuring Device, Manual Warewashing; Sanitizing Solutions, Testing Device (Pf) (h) Temperature Measuring Devices, Manual and Mechanical Warewashing.
In manual warewashing operations, a temperature measuring device shall be provided and readily accessible for frequently measuring the washing and sanitizing temperatures. Pf
In hot water mechanical warewashing operations, an irreversible registering temperature indicator shall be provided and readily accessible for measuring the utensil surface temperature. Pf
(i) Sanitizing Solutions, Testing Devices. A test kit or other device that accurately measures the concentration in mg/L of sanitizing solutions shall be provided. Pf
Regulation: 511-6-1.07(2)(l) - toilet rooms, enclosed (c)
Employee restroom door does not self-close. Advise- provide a self-closing mechanism for the restroom door.
Routine
Observed ceiling being painted in the facility at the same time as food prep. COS-painting discontinued. Advised PIC to preform maintenance during non-operating hours.
Regulation: 511-6-1.03(5)(j) - hair restraints (c)
Employee preparing food wearing a visor and not properly restraining hair. Advised PIC to use hats or hairnets under the visor.
Regulation: 511-6-1.05(2)(cc) - warewashing, automatic dispensing of detergents and sanitizers (pf)
Observed the dish machine set up incorrectly, no soap feeding unit, and QAC sanitizer feed machine. COS- unit use discontinued until serviced, only use the 3-compartment sink to wash, rinse, and sanitize. Advised PIC to discontinue use of machine until serviced and correct chemicals are installed.
Routine
Regulation: 511-6-1.05(10)(e)1,2,4 - equipment, utensil, linens, stored 6" off floor in clean, dry location (c)
Observed utensils being stacked wet. COS PIC separated to air dry. Advised PIC to let utensils always completely air dry before stacking.