Oct 7, 2025
Routine
18 - combined chlorine level 0.4 ppm or less
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Combined chlorine measured 0.6 ppm. See readings log. Corrective action: The combined chlorine shall measure 0.4 ppm lor less.
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meters do not appear to be functioning; float not moving. Corrective action: The flow meters shall measure the flow rate at approximately 360 GPM for your pool. Advise PIC to replace the flow meter with an adequate flow meter that can measure 360 GPM; the flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate.