Alpharetta, Fulton County

The Chelsey Outdoor Pool

300 CHELSEY CT ALPHARETTA, GA 30004

Pool
Latest score
100
May 5, 2026
City
Alpharetta
County
Fulton
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 5, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 20, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 14, 2025

Permit/Opening

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed a flow rate of 0. Upon further investigation, EHS observed an issue with pump. The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer's recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Observed two broken returns for the facility. The fitting shall not constitute a hazard to the user.

Jun 3, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 22, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.