Atlanta, Fulton County

500 Northside Apartments

500 NORTHSIDE CIR NW ATLANTA, GA 30309

Pool
Latest score
100
May 8, 2026
City
Atlanta
County
Fulton
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 8, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 22, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 12, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 11, 2024

Re-inspection

Score: 802 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone not in operation at time of inspection. operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby. AT&T to visit and repair phone.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Observed flow meter at 40gpm, putting flow rate at over 9 hours. Turnover rate at 14 hours. The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. CPO to fix flow.

May 29, 2024

Permit/Opening

Score: 676 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(a) - (11) barriers. all outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) the top of the barrier shall be at least forty eight inches above grade maesured on the side of the bar

15 ptsCorrected: NoRepeat: No

Observed pool fence broken in mulitple places. Observed unapproved fencing surrounding pool. All outdoor swimming pools and spas shall be enclosed by a barrier to prevent entry to the pool area when the pool is closed. (a) The top of the barrier shall be at least forty eight inches above grade maesured on the side of the barried which faces away from the swiming pool. 1. The maximim vertical clearance between a solid surface and the bottom of the barrier shall be four inches measured on the side of the barrier which faces away from the swimming pool. 2. For non-solid surfaces, the veritical clearance between the bottom of the barrier and the grade shall not exceed two inches for a barrier constructed after adoption of the chapter. 3. Where the top of the pool structure is above grade, the barrier may be at ground level, such as the pool structure. 4. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be four inches. CPO will have pool fence repaired.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

PH exceeded 8.0. Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180 ppm as CaC03 100-120 halogen compounds with low pH Calcium hardness, ppm, CaCo3 150 200-400 to balance water 1000

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Turnover rate at 14 hours. The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer's recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(1) - (1) all swimming pools and spas covered by this chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equ

5 ptsCorrected: NoRepeat: No

No logs kept on site. All swimming pools and spas covered by this Chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equipment, and for and daily recordkeeping.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

All skimmers missing weirs. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanauric acid exceeded 100. 4) Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: - May reduce chlorine efficacy Too Low: - Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.

May 25, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.