Mar 12, 2026
Routine
3 - hot/cold running water under pressure in all required locations of tourist accommodation
Regulation: 511-6-2-.07(2) - hot water supply
Observed hot water above 120 degrees in multiple rooms. CA: Advised PIC to lower water temperature.
511-6-2-.07(2) - Hot Water Supply Cold running water under pressure shall be provided to all equipment that uses water. Hot and cold running water under pressure shall be provided to all lavatories, bathing facilities, laundry facilities, and water-using equipment where eating and drinking utensils are washed. In all new tourist accommodations, and where possible in existing tourist accommodations, hot water in all guest rooms shall not exceed 120F
26 - ventilation provided and lighting adequate; guestroom kitchenettes/cooking facilities approved
Regulation: 511-6-2-.14(3) - room ventilation
Observed ventilation not operating in multiple bathrooms. CA: Advised PIC to get ventilation system serviced.
511-6-2-.14(3) - Room Ventilation Ventilation shall be provided for all rooms. Where ventilation is provided by means of windows, they shall open directly to the outside air and the openable window area of each room shall be not less than 1/20 of the floor area served. Where ventilation is provided by other means, it shall comply with the requirements of the current International Mechanical Code with Georgia Amendments or future subsequent revisions adopted thereafter to provide comfortable living conditions, remove objectionable odor and fumes, and prevent excessive condensation. Ventilation systems shall comply with applicable State and local fire prevention requirements and building codes