College Park, Fulton County

Holiday Inn & Suites Atlanta Airport North

1380 VIRGINIA AVE ATLANTA, GA 30344

Pool
Latest score
84
May 22, 2026
City
College Park
County
Fulton
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 22, 2026

Permit/Opening

Score: 843 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.23(5)(g) - (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

15 ptsCorrected: YesRepeat: No

Observed the gate is not secure.

511-3-5-.23(5)(g) - (g) Failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required. (g) Failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: YesRepeat: No

Observed the gate has been bent.

511-3-5-.18(11)(b) - (b) Openings in the barrier shall not allow passage of a four inch diameter sphere. (b) Openings in the barrier shall not allow passage of a four inch diameter sphere.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pool need to be re-surface by next pool season 2027.

May 5, 2026

Permit/Opening

Score: 953 violations

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

Observed missing return cover at 4 ft. Shall provide covers

511-3-5-.10(1)(c )1.ii. - (ii) The fitting shall not constitute a hazard to the user. (ii) The fitting shall not constitute a hazard to the user.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed piping on return line leaking. Shall repair

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed missing Walter line tiles at 6 feet.

Apr 23, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 30, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 8, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.