East Point, Fulton County

Hilton Garden Inn Atlanta Airport North Whirlpool

3437 BOBBY BROWN PKWY ATLANTA, GA 30344

Pool
Latest score
85
May 26, 2026
City
East Point
County
Fulton
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 26, 2026

Routine

Score: 851 violation

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed water cloudy and pool room overheated. 511-3-5-.07(1)(e ) - (e) Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. When standing at a spa's e (e) Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. When standing at a spa's edge, the deepest portion of the spa floor shall be visible when the water is still. 1. For pools over ten feet deep an eight inch by eight inch square marker tile in a contrasting color to the pool floor shall be visible at all deepest part of the pool. 2. This reference point shall be visible at tall times from the edge of the deck.times from the edge of the deck. Instructed PIC to flush out the pool and put a temporary close sign on pool door till the problem is fixed and we come out for reinspection.

Jul 21, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 14, 2025

Permit/Opening

Score: 853 violations

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed water cloudy. 511-3-5-.07(1)(e ) - (e) Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. When standing at a spa's e (e) Water clarity shall be maintained. When standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. When standing at a spa's edge, the deepest portion of the spa floor shall be visible when the water is still. 1. For pools over ten feet deep an eight inch by eight inch square marker tile in a contrasting color to the pool floor shall be visible at all deepest part of the pool. 2. This reference point shall be visible at tall times from the edge of the deck.times from the edge of the deck.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone is out and have no dial tone. 511-3-5-.18(10)(c ) - (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed the chlorine at 0 ppm. CA- the chlorine shall be between 1-10 ppm. .17(1)(a)(b): (1) Disinfectant Levels: (a) Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0

Jul 17, 2024

Permit/Opening

Score: 802 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: Yes

Observed the chlorine pass 10 ppm. CA- the chlorine shall be between 1-10 ppm. .17(1)(a)(b) - Proper disinfectant level (1) Disinfectant Levels (a) Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: Yes

Observed the flow meter not working, CA- flow meter shall be working to calculate the required turnover rate. 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

Jul 16, 2024

Permit/Opening

Score: 764 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed the chlorine pass 10 ppm. CA- the chlorine shall be between 1-10 ppm. .17(1)(a)(b) - Proper disinfectant level (1) Disinfectant Levels (a) Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed the pH below 7.2. CA- the pH shall be between 7.2 and 7.8 at all times. 511-3-5-.23(5)(b) - (b) During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7. (b) During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed the flow meter not working, CA- flow meter shall be working to calculate the required turnover rate. 511-3-5-.07(4)(b) - (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

Observed an expired CPO certification. CA- CPO shall not be expired. 511-3-5-.22(2) - (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. New Violation.

Dec 20, 2023

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: YesRepeat: No

Observed the chlorine at 0 pm. COS- pool operator added chlorine to the chemical feeder and added chlorine into the spa and chlorine was brought up to 10. The chlorine is now at the maximum amount. 17((1)(c) - Proper disinfectant level (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

Jun 29, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.