Hapeville, Fulton County

Blue Atlantic Hartsfield, LP

3640 S FULTON AVE HAPEVILLE, GA 30354

Pool
Latest score
82
Jun 9, 2026
City
Hapeville
County
Fulton
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 9, 2026

Re-inspection

Score: 824 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed failure of main gate to self-latch

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH level below minimum

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed loose handrails

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed low alkalinity level

May 13, 2026

Permit/Opening

Score: 776 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed main entrance door failure to self-latch.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine level below minimum.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH level below minimum

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Observed lifesaver ring in disrepair

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid level exceeding maximum

32 - operator training certification available onsite and approved

Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.

4 ptsCorrected: NoRepeat: No

Observed expired CPO certificate.

Jun 29, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 23, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 22, 2023

Re-inspection

Score: 991 violation

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Missing weir. Code: 11(3)(d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Jun 21, 2023

Permit/Opening

Score: 825 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

chlorine too high. lower to 10 ppm max. Code> (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH over 8. lower to 7.8 max. Code> (2) Chemical Values: pH 7.2 7.4-7.6 7.8.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.16(2)(a) - (a) every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule

15 ptsCorrected: NoRepeat: No

Feeder not calibrated to send proper balance of chemicals to pool. calibrate feeder.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

handrail in pool needs tightening.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

missing weir. Code: 11(3)(d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.