Palmetto, Fulton County

Palmetto Preserve

9100 CASCADE PALMETTO HWY PALMETTO, GA 30268

Pool
Latest score
71
Jun 16, 2023
City
Palmetto
County
Fulton
Inspections
1

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 16, 2023

Permit/Opening

Score: 716 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone must connect to emergency services when activated without having to activate phone; phone clarity is distorted and must activated by pressing DIAL before a dial tone is heard. C/A: Repair or replace phone to one that connects to emergency services directly.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Replace inoperable flow meter to provide accurate reading.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid levels must be maintained less than 90 ppm; level was over 100ppm at time of inspection

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

Observed missing bump guards at feet of step ladder C/A: provide missing bump guard

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Observed pool coping with a sharp exposed edges. C/A: Repair pool coping with sharp edges

29 - toilets & lavatories: clean, maintained, and stocked

Regulation: 511-3-5-.19(2)(n) - (n) sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an epa-approved product and as needed to provide a clean and sanitary environment.

1 ptsCorrected: NoRepeat: No

Observed a failure to maintain lavatory facilities in a clean, sanitary manner or in good repair. C/A: Repair holes in walls, provide receptacles in bathroom where necessary.