Union City, Fulton County

ZAXBY'S

6801 STUDIO WAY UNION CITY, GA 30291

Food
Latest score
99
Sep 9, 2025
City
Union City
County
Fulton
Inspections
2

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Sep 9, 2025

Routine

Score: 991 violation

14A - in-use utensils: properly stored

Regulation: 511-6-1.04(4)(k) - in-use utensils, between-use storage (c)

1 ptsCorrected: YesRepeat: No

Observed ice scoop with handle in contact with ice. Advised PIC to remove handle from ice and make sure it is in a contained separate from ice machine.

Jul 1, 2025

Initial

Score: 936 violations

18 - insects, rodents, and animals not present

Regulation: 511-6-1.07(2)(m) - outer openings protected (c)

3 ptsCorrected: NoRepeat: No

Observed flies in prep areas and front service line. Air curtain at drive thru door is not strong enough to keep flies out. Door stands open too long.

511-6-1.07(2)(m) - Outer Openings Protected (C) (m) Outer Openings, Protected.

  1. Except as specified in paragraphs 2 through 5 of this subsection, outer openings of a food service establishment shall be protected against the entry of insects and rodents by:

(i) Filling or closing holes and other gaps along floors, walls, and ceilings;

(ii) Closed, tight-fitting windows; and

(iii) Solid, self-closing, tight-fitting doors.

  1. The requirements in paragraph 1 of this subsection does not apply if a food service establishment opens into a larger structure, such as a mall, airport, or office building, or into an attached structure, such as a porch, and the outer openings from the larger or attached structure are protected against the entry of insects and rodents.

  2. Exterior doors used as exits need not be self-closing if they are:

(i) Solid and tight-fitting;

(ii) Designated for use only when an emergency exists, by the fire protection authority that has jurisdiction over the food establishment; and

(iii) Limited-use so they are not used for entrance or exit from the building for purposes other than the designated emergency exit use.

  1. Except as specified in paragraphs 2 and 5 of this subsection, if the windows or doors of a food service establishment, or of a larger structure within which a food service establishment is located, are kept open for ventilation or other purposes or a temporary food service establishment is not provided with windows and doors as specified under paragraph 1 of this subsection, the openings shall be protected against the entry of insects and rodents by:

(i) 16 mesh to 1 inch (16 mesh to 25.4 mm) screens;

(ii) Properly designed and installed air curtains to control flying insects; or

(iii) Other effective means.

  1. The requirement in paragraph 4 of this subsection does not apply if flying insects and other pests are absent due to the location of the establishment, the weather, or other limiting condition.

16A - hot and cold water available; adequate pressure

Regulation: 511-6-1.06(1)(g),(h) - water supply, capacity; pressure (pf)

2 ptsCorrected: NoRepeat: No

Observed no Hot water supply at prep sink. Must provide within 10 days.

511-6-1.06(1)(g),(h) - Water Supply, Capacity; Pressure (Pf) (g) Capacity.

  1. The water source and system shall be of sufficient capacity to meet the peak water demands of the food service establishment. Pf

  2. Hot water generation and distribution systems shall be sufficient to meet the peak hot water demands throughout the food service establishment. Pf (h) Pressure. Water under pressure shall be provided to all fixtures, equipment, and nonfood equipment that are required to use water except that water supplied as specified under subsection (1)(k)1 and 2 to a temporary food service operation or in response to a temporary interruption of a water supply need not be under pressure. Pf

16B - plumbing installed; proper backflow devices

Regulation: 511-6-1.06(2)(r) - system maintained in good repair (p, c)

2 ptsCorrected: NoRepeat: No

Observed leaking pipe at hand sink. Must repair within 10 days.

511-6-1.06(2)(r) - System Maintained in Good Repair (P, C) (r) System Maintained in Good Repair. A plumbing system shall be repaired according to law; P and maintained in good repair.

15A - food and nonfood-contact surfaces cleanable, properly designed, constructed, and used

1 ptsCorrected: NoRepeat: No

Observed prep top cooler note working properly. Facility using ice to hold food at proper cold holding temperature.

15C - nonfood-contact surfaces clean

Regulation: 511-6-1.05(7)(d) - nonfood-contact surfaces (c)

1 ptsCorrected: YesRepeat: No

Observed buildup of soiled material on food containers handles, drawer cooler, handles and equipment handles. Manager cleaned handles.

511-6-1.05(7)(d) - Nonfood-Contact Surfaces (C) (d) Nonfood-Contact Surfaces. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(2)(a) - floor, walls, & ceilings, cleanability (c)

1 ptsCorrected: NoRepeat: No

Observed holes/damaged ceiling tile above storage ranks.