16 - pool deck: maintained, unobstructed and clean
Observed pool surface damaged at the time of this inspection. CA: Pool will need to be resurfaced by the 2027 season or permit may not be issued.
201 ARNOLD RD SAINT SIMONS ISLAND, GA 31522
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Observed pool surface damaged at the time of this inspection. CA: Pool will need to be resurfaced by the 2027 season or permit may not be issued.
Routine
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Observed combined chlorine above 0.4ppm at the time of this inspection. CA: Lower combined chlorine.
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
Observed pool surface damaged at the time of this inspection. CA: Pool will need to be resurfaced by the 2027 season or permit may not be issued.
Permit/Opening
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
Observed pool surface damaged at the time of this inspection. CA: Prepare to resurface by the next off season.
Routine
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Observed combined chlorine above 0.4ppm at the time of this inspection. CA: Lower combined chlorine.
Permit/Opening
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
Observed pool surface damaged at the time of this inspection. CA: Prepare to resurface by the next off season.
Routine
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed CYA above 90ppm at the time of this inspection. CA: Lower to 90ppm or less
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
Observed pool surface damaged at the time of this inspection. CA: Prepare to resurface soon.