Apr 10, 2026
Permit/Opening
515 WINDWARD DR SAINT SIMONS ISLAND, GA 31522
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.
Observed pool surfacing has multiple spots with surfacing peeling away leaving holes at the time of this inspection. CA: Repair/resurface pool before next year's permitting inspection.
Routine
Routine
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Observed CYA above 90ppm at the time of this inspection. CA: Lower to 90ppm or less.
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
Observed missing tiles on inside rim of pool. CA: Replace missing tiles and grout to smooth finish.