Buford, Gwinnett County

HOME 2 SUITES

2685 Mall of Georgia Blvd Buford GA 30519

Tourist
Latest score
98
Apr 10, 2026
City
Buford
County
Gwinnett
Inspections
3

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 10, 2026

Routine

Score: 981 violation
Comments

Note: An informal inspection will occur by 4/20/2026. Total Rooms: 95 Rooms Inspected: 114, 216 (so), 224, 225, 200, 300 (so), 309, 414 , 420. Questions? (770)-963-5132 www.gnrhealth.com

-

Corrected: NoRepeat: No

23: .13(2)Observed pest control records missing from March 2026, December 2025, and December 2024. [.13(2)] A record must be maintained on file and available at request of Health Authority for no less than 18 months of any pesticide use on the premises, except for the occasional use of consumer insect sprays on small spots in accordance with the product label. The record may be made by the permit holder or provided by the applicator, and shall list the following information: (a) amount and concentration of product used; (b) name of product used; (c) date and location of application; (d) application method; (e) pest targeted; and (f) name of applicator.

Dec 15, 2025

Routine

Score: 932 violations
Comments

QUESTIONS: 770-963-5132 or www.gnrhealth.com NOTE: Thermometer calibrated today at the office (ice bath 32F). Rooms inspected: 118, 205, 219, 229, 300, 321, 329, 405, 410

-

Corrected: YesRepeat: No

8: .15(5)Facility has 7 water heaters on second floor, 1 tankless water heater on the first floor and 3 dryers in the laundry room. Facility also has 2 gas grills and a gas fire pit outside. Person in charge (PIC) provided an invoice dated 11/3/2025 copy of the invoice attached). PIC stated the units were inspected but reports could not be generated at the time of inspection. All gas-fired equipment shall be inspected at least annually by a qualified licensed contractor or local fire authority, if available. Points to be inspected are proper construction and installation, malfunctions and adjustments of controls and burners, faulty heat exchangers and vent obstructions. Any defects found on inspection must be corrected by a qualified heating contractor prior to use of the equipment. Upon request, the operator shall provide evidence of inspection and/or correction of any deficiency. Corrective Actions: PIC stated the inspection reports will be emailed by Wednesday 12/17/2025.

-

Corrected: YesRepeat: No

16: .08(4)Observed bathroom exhaust fans in room 405 and 410 have accumulation of dust. Observed AC units in room 321, 329 and 405 have accumulation of dust. [.08(4)] Toilet rooms and fixtures must be smooth and nonabsorbent and shall be kept clean and in good repair. Walls, floors, and ceilings shall be constructed of easily cleanable nonabsorbent materials and shall be kept clean and in good repair. While being used by tourists, every surface of a bathtub, shower, shower enclosure, toilet and lavatory, which may come in contact with a person's body, must be sanitized each day, unless the guest has declined regular tourist room services. If a tourist declines regular tourist room services, the tourist accommodation facility must ensure that these surfaces are cleaned and sanitized at least once per week and between tourists. Corrective Actions: Maintenance staff cleaned the exhaust fans and AC units.

Jun 17, 2025

Routine

Score: 1000 violations
Comments

Rooms inspected: 114, 120, 123, 225, 304 (stayover), 314 (stayover), 323, 406, 407 Note: Ensure that toilet brushes are adequately separated from clean linens and single use items on rolling carts. Note: Joint inspection with LMB. Questions/comments? 770-963-5132 or gnrhealth.com

No violations recorded for this inspection.