Apr 22, 2026
Routine
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
The existing flow meter is inoperable and in disrepair; advised PIC to replace equipment in question and notify the Health Authority upon completion of repairs.
34 - inspection report placed in public view
Regulation: 511-3-5-.23(3)(d) - (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
The inspection report was not displayed for public viewing; a copy of the most recent report shall be displayed for public viewing in accordance with Georgia law.