Flowery Branch, Hall County

PEYTONS PIE COMPANY

5609 MAIN ST STE A FLOWERY BRANCH, GA 30542

Food
Latest score
93
Dec 11, 2025
City
Flowery Branch
County
Hall
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Dec 11, 2025

Routine

Score: 932 violations

4-2B - food-contact surfaces: cleaned & sanitized

Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)

4 ptsCorrected: NoRepeat: Yes

The dish washing machine at the front customer service area and bar measured 0ppm of chlorine when tested with a chemical test kit. 511-6-1.05(6)(n) - Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration, Hardness (P,Pf) (n) Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration, and Hardness. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows:

  1. A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart; P

Concentration Range Minimum Temperature

MG/L PH 10 or less oF (oC) PH 8 or less oF (oC)

25-49 120 (49) 120 (49)

50-99 100 (38) 75 (24)

100 55 (13) 55 (13) Note: The facility will need to have both dishwashing machine repaired and will need to use the 3-compartment sink or the back of house dishwasher to sanitize utensils and equipment.

17C - physical facilities installed, maintained, and clean

Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)

1 ptsCorrected: NoRepeat: No

Observed several gaskets through the facility of reach-in coolers and walk-in coolers to be in disrepair. 511-6-1.07(5)(a),(b) - Good Repair, physical facilities maintained; Cleaning, Frequency & Restrictions, cleaned often enough to keep them clean (C) (5) Maintenance and Operation. (a) Good Repair. All physical facilities shall be maintained in good repair. Note: The facility will need to clean/sanitize gaskets or replace as needed.

May 15, 2025

Routine

Score: 932 violations

4-2B - food-contact surfaces: cleaned & sanitized

Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)

4 ptsCorrected: YesRepeat: No

The dish washing machine at the front customer service area measured 0ppm of Chlorine when tested with a Chemical Test kit. 511-6-1.05(6)(n) - Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration, Hardness (P,Pf) (n) Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration, and Hardness. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows:

  1. A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart; P

Concentration Range Minimum Temperature

MG/L PH 10 or less oF (oC) PH 8 or less oF (oC)

25-49 120 (49) 120 (49)

50-99 100 (38) 75 (24)

100 55 (13) 55 (13) Note: The facility will use the dish machine in the kitchen, until the mini dish machine at the front customer service area is repaired.

11D - thermometers provided and accurate

Regulation: 511-6-1.05(2)(x) - tmd, located in refrigerators/ hot holding (pf, c)

3 ptsCorrected: YesRepeat: No

No thermometer was observed in the reach in cooler unit by the Pizza Oven. 511-6-1.05(2)(x) - TMD, Located in Refrigerators/ Hot Holding (Pf, C) (x) Temperature Measuring Devices.

  1. In a mechanically refrigerated or hot food storage unit, the sensor of a temperature measuring device shall be located to measure the air temperature in the warmest part of a mechanically refrigerated unit and in the coolest part of a hot food storage unit.

  2. Except as specified in paragraph 3 of this subsection, cold or hot holding equipment used for time/temperature control for safety food shall be designed to include and shall be equipped with at least one integral or permanently affixed temperature measuring device that is located to allow easy viewing of the device's temperature display.

  3. The requirement in paragraph 2 of this subsection does not apply to equipment for which the placement of a temperature measuring device is not a practical means for measuring the ambient air surrounding the food because of the design, type, and use of the equipment such as insulated food transport containers and salad bars.

  4. Temperature measuring devices shall be designed to be easily readable.

  5. Food temperature measuring devices and water temperature measuring devices on warewashing machines shall have a numerical scale, printed record, or digital readout in increments no greater than 1ºC or 2ºF in the intended range of use. Pf. Note: Manager placed a thermometer in the unit during the inspection.

Jul 22, 2024

Routine

Score: 962 violations

4-2B - food-contact surfaces: cleaned & sanitized

Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)

4 ptsCorrected: YesRepeat: No

Observed no sanitizer to be set up in facility.

A quaternary ammonium compound solution shall have a minimum temperature of 75ºF (24ºC), P have a concentration as specified in DPH Rule 511-6-1-.07(6)(g) and as indicated by the manufacturer’s use directions included in the labeling, P and be used only in water with 500 ppm hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions

Note: PIC immediately set up a sanitizer bucket.

4-2B - food-contact surfaces: cleaned & sanitized

Regulation: 511-6-1.05(7)(b) - food contact surfaces and utensils - cleaning frequency (p, c)

4 ptsCorrected: NoRepeat: No

Observed accumulation of soil in soda nozzles.

In equipment such as ice bins and beverage dispensing nozzles and enclosed components of equipment such as ice makers, cooking oil storage tanks and distribution lines, beverage and syrup dispensing lines or tubes, coffee bean grinders, and water vending equipment:

(I) At a frequency specified by the manufacturer; or

(II) Absent manufacturer specifications, at a frequency necessary to preclude accumulation of soil or mold.

Note: PIC will sanitize nozzles and ensure there is no accumulation of soil.

Jan 23, 2024

Routine

Score: 961 violation

2-2D - adequate handwashing facilities supplied & accessible

Regulation: 511-6-1.06(2)(o) - using a handwashing sink- operation & maintenance (pf)

4 ptsCorrected: NoRepeat: No

Observed hand sink being used to dump drinks and ice.

A handwashing facility may not be used for purposes other than handwashing.

Note: PIC will use another sink for dumping drinks.