Dec 11, 2025
Routine
4-2B - food-contact surfaces: cleaned & sanitized
Regulation: 511-6-1.05(6)(n) - manual and mechanical warewashing equipment, chemical sanitization-temperature, ph, concentration, hardness (p,pf)
The dish washing machine at the front customer service area and bar measured 0ppm of chlorine when tested with a chemical test kit. 511-6-1.05(6)(n) - Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration, Hardness (P,Pf) (n) Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration, and Hardness. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows:
- A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart; P
Concentration Range Minimum Temperature
MG/L PH 10 or less oF (oC) PH 8 or less oF (oC)
25-49 120 (49) 120 (49)
50-99 100 (38) 75 (24)
100 55 (13) 55 (13) Note: The facility will need to have both dishwashing machine repaired and will need to use the 3-compartment sink or the back of house dishwasher to sanitize utensils and equipment.
17C - physical facilities installed, maintained, and clean
Regulation: 511-6-1.07(5)(a),(b) - good repair, physical facilities maintained; cleaning, frequency & restrictions, cleaned often enough to keep them clean (c)
Observed several gaskets through the facility of reach-in coolers and walk-in coolers to be in disrepair. 511-6-1.07(5)(a),(b) - Good Repair, physical facilities maintained; Cleaning, Frequency & Restrictions, cleaned often enough to keep them clean (C) (5) Maintenance and Operation. (a) Good Repair. All physical facilities shall be maintained in good repair. Note: The facility will need to clean/sanitize gaskets or replace as needed.