WARM SPRINGS, Harris County

Mountain Top Inn & Resort

177 ROYAL LODGE DR WARM SPRINGS, GA 31830

Pool
Latest score
100
May 15, 2026
City
WARM SPRINGS
County
Harris
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 15, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 8, 2026

Permit/Opening

Score: 797 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: NoRepeat: No

Observed opening under the barrier fence greater that 4 inches. This area is near the emergency phone. Barriers must maintain openings less than 4 inches.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed ring buoy cracked in multiple places. Ring buoy needs replacement.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Observed depth marker missing on deck at 3 ft.. Place depth marker and no diving on deck at 3 ft.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

No diving/universal sign missing on deck at 3 ft. depth.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Missing accurate No Lifeguard on Duty sign postage.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed theoretical peak occupancy not posted. Theoretical peak occupancy must be posted.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Pool risks # 4, 5, 7, 8, 9, and 10 missing from signage.

May 15, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 18, 2024

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 6, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 29, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 26, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.