Jan 7, 2026
Permit/Opening
1601 LEVERETTE RD WARNER ROBINS, GA 31088
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Re-inspection
Routine
Observed free chlorine to be very high at over 40ppm. The allowable range for free chlorine is 2ppm-10ppm. Reduce free chlorine to within allowable range.
Observed pH low at 7.0. The allowable range is 7.2-7.8. Increase pH to within allowable range.
Observed low flow rate at 38gpm. The minimum flow rate allowed is 85gpm. The record binder shows flows recently over 100. Correct flow rate (backwash/clean flowmeter etc) so the flow is 85gpm or higher.
Observed cyanuric acid greater than 100ppm. The rules state that the ideal range for cyanuric acid is 30-50, but can be at a maximum of 90. Recommend removing some pool water to lower the cyanuric acid to below 90. Replacing pool water will also lower the free chlorine level.
Routine
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Cyanuric acid was found to be greater than 100. The rules state that the ideal range for cyanuric acid is 30-50, but can be at a maximum of 90. Recommend removing some pool water to lower the cyanuric acid to below 90.
Permit/Opening
Routine
Permit/Opening
Permit/Opening