320 CARL VINSON PKWY WARNER ROBINS, GA 31088
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Re-inspection
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed no flow indicator bobble inside of the flow meter to measure the rate of flow. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. Repair the flow meter so that it can read the flow.
Routine
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Observed the chlorine concentration at 0.5ppm during operation. The allowable range is 1-10ppm without stabilizer or 2-10ppm with stabilizer. Add chlorine to pool to being it to the allowable range.
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Observed the pH below a 7.0ppm during operation. The allowable range for pH is 7.2-7.8ppm. Add chemicals to raise the pH to the allowable range.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed the flow meter indicator bobble stuck at the bottom and not moving. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. Repair the flow meter so that it can read the flow.
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
Observed no POOL RISK sign posted in the pool area. A POOL RISK sign shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high. Place the POOL RISK sign in the pool area for public view.
Observed total alkalinity at 30ppm. The allowable range for total alkalinity is 60-180ppm. Add chemicals to pool to raise alkalinity.
Permit/Opening
Permit/Opening
Routine