Jun 9, 2026
Routine
5473 MT OLIVE RD COMMERCE, GA 30529
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
Permit/Opening
Routine
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Cyanuric acid was observed to be at 100ppm. Reduce cyanuric acid to below 90ppm.
Permit/Opening
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Pool was voluntarily closed at arrival. Pool cannot re-open until emergency phone is operable.
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Ensure adequate turnover rate is met
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter pipe size incorrect.
Permit/Opening
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Ensure adequate turnover rate is met
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter pipe size incorrect.
Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
Piping not identified and marked with directional arrows
Routine
Ensure adequate turnover rate is met
Cyanuric acid exceeds maximum. 30-50 ppm ideal
Permit/Opening
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Ensure adequate turnover rate is met to ensure 6 hour turnover