Mar 30, 2026
Permit/Opening
42 GALLEY LN MIDWAY, GA 31320
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Gate does not self-close and latch. Gate is catching on fence post.
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Observed free chlorine of greater than 10ppm
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Observed flowrate less than required for 6hr turnover. Flow rate should be approx 64GPM.
Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Observed no evidence of twice daily chemical testing.
Observed weir missing from skimmer on south end of pool.
Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Observed no evidence of written records of operator inspections/visits
Permit/Opening
Routine
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed skimmer missing from weir on south end of pool.
Routine
Permit/Opening
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter was not functioning at the time of the inspection. CA: CPO informed that the flow meter would need to be fixed or replaced in order to assure it is calculating the GPM of the pool.