Apr 8, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 8, 2025

Routine

Score: 912 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Observed no record keeping with the new company that became the CPO for the subdivision, all records need to be kept daily about the chemical of the pools. Will call and make sure that the CPO keep records of pool they are maintaining for Greystone subdivision

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed 2 missing weirs in the skimmers at the pool site, ) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. The CPO will replace the weirs before next year opening.

Aug 14, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 2, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 12, 2024

Routine

Score: 912 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Observed one of the flow meters not working properly, all flow meter should be working to give a turnover rate of the pool within the six-hour window. Fix by 08/30/2024

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

Missing a weir in the skimmer of the pool fix by 08/30/2024

Jul 18, 2024

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Observed one of the flow meters not working properly, all flow meter should be working to give a turnover rate of the pool within the six-hour window. Fix by 07/30/2024

May 3, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 21, 2023

Routine

Score: 902 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: Yes

Observed one of the flow meters not working properly, all flow meter should be working to give a turnover rate of the pool within the six-hour window. Will call the HOA and see if the can get the other flow meter operational

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: Yes

Observed no record keeping with the new company that became the CPO for the subdivision, all records need to be kept daily about the chemical of the pools. Will call and insure that the CPO keep records of pool they are mainaining for Greystone subdivision

Jul 28, 2023

Routine

Score: 902 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed one of the flow meters not working properly, all flow meter should be working to give a turnover rate of the pool within the six-hour window. Will call the HOA and see if the can get the other flow meter operational

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

Observed no record keeping with the new company that became the CPO for the subdivision, all records need to be kept daily about the chemical of the pools. Will call and insure that the CPO keep records of pool they are mainaining for Greystone subdivision

May 18, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.