Jun 4, 2026
Permit/Opening
1309 29TH ST COLUMBUS, GA 31904
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Observed flee chlorine level at 1.2ppm. Fee chlorine shall be 2-10ppm.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed PH level at 8.0. pH shall be 7.2-7.8.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter reading at 90. Minimum flow rate for pool shall be 175. Observed flow meter able to read a max of 120. A flow meter measuring the rate of flow through filter system with an appropriate range shall be provided.
Re-inspection
Routine
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Observed pH for pool at 8.0. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7.
Permit/Opening
Re-inspection
Permit/Opening
Regulation: 511-3-5-.07(1)(b) - (b) turnover rates for pools by type listed below: type
Observed flow meter not reaching adequate turnover rate. Observed flow meter readings around 65 GPM and 85 GPM to give a total of 150 GPM. Must be working properly to ensure an adequate turnover rate. Must correct violation before pool can be permitted for the 2024 pool season.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Observed weir gate missing in one of the skimmer systems. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. Must correct before pool can re-inspected.