Columbus, Muscogee County

TOWNE PLACE SUITES POOL

4534 ARMOUR RD COLUMBUS, GA 31904

Pool
Latest score
100
Apr 10, 2026
City
Columbus
County
Muscogee
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Apr 10, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 18, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 15, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Oct 3, 2024

Re-inspection

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed facility's pH level at 8.0. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7. pH must be between 7.2 and 7.8.

Aug 26, 2024

Routine

Score: 794 violations

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed facility's pH level at 7.0. During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7. pH must be between 7.2 and 7.8.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter not working. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed total alkalinity at 40ppm. Total Alkalinity must be between 60 to 180ppm.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed calcium hardness at 110ppm. Calcium hardness must be between 150 to 1000ppm.

May 3, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.