Dec 11, 2025
Routine
6 - proper disinfectant level
Regulation: .17(1)(a)(b) - proper disinfectant level
Observed free chlorine level concentration at 0ppm. Free Chlorine shall range from 1ppm-10ppm.
7 - ph between 7.2 and 7.8
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed pH level too high, reading at greater than 8.0. pH shall range from 7.2 - 7.8.
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not working properly. Unable to determine flow rate of pool. A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided.
12 - grab/hand rails, ladders installed and secure
Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.
Observed handrail by the pool entry steps loose and unsecure. Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.