Mar 31, 2026
Permit/Opening
461 PARKWEST DR GROVETOWN, GA 30813
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Increase flow meter, gpm observed at 20 gpm instead of at minimum of 42 gpm. CA: Increase flow to reach required minimum.
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter reading at 18 gpm, instead of 42 gpm. CA: Increase flow to reach required level.
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Observed daily log book not being maintained. CA: Must take readings twice a day daily to ensure pool levels are correct.
Permit/Opening