ANDERSONVILLE, Sumter County

Oakwood RV Park

903 HWY 49 ANDERSONVILLE, GA 31711

Tourist
Latest score
98
Feb 5, 2026
City
ANDERSONVILLE
County
Sumter
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Feb 5, 2026

Routine

Score: 981 violation

10 - permit and inspection report current and properly displayed; pic assigned

2 ptsCorrected: NoRepeat: Yes

Did not observe the active permit posted in public view. The most recent tourist accommodation inspection report form shall be prominently displayed in public view at all times, between five feet and seven feet from the floor and in a public area such as the registration desk, where it can be read at a distance of one foot away

Jun 25, 2025

Routine

Score: 981 violation

10 - permit and inspection report current and properly displayed; pic assigned

2 ptsCorrected: NoRepeat: Yes

Did not observe the active permit or last inspection report posted. The most recent tourist accommodation inspection report form shall be prominently displayed in public view at all times, between five feet and seven feet from the floor and in a public area such as the registration desk, where it can be read at a distance of one foot away

Dec 16, 2024

Routine

Score: 981 violation

10 - permit and inspection report current and properly displayed; pic assigned

2 ptsCorrected: NoRepeat: Yes

Did not observe the active permit posted. The most recent tourist accommodation inspection report form shall be prominently displayed in public view at all times, between five feet and seven feet from the floor and in a public area such as the registration desk, where it can be read at a distance of one foot away

Jun 26, 2024

Routine

Score: 981 violation

10 - permit and inspection report current and properly displayed; pic assigned

Regulation: 511-6-2-.05(7) - inspection posting

2 ptsCorrected: NoRepeat: No

Did not observe the previous inspection report posted or the active permit. The most recent tourist accommodation inspection report form shall be prominently displayed in public view at all times, between five feet and seven feet from the floor and in a public area such as the registration desk, where it can be read at a distance of one foot away

Jan 2, 2024

Re-inspection

Score: 886 violations

1 - adequate, approved, permitted, protected potable water supply; no cross connection or back siphonage

Regulation: 511-6-2-.07(1)(b) - water supply and sanitizing - nonpublic

5 ptsCorrected: NoRepeat: No

Observed no quarterly bacteriological or yearly chemicals and metals water sample results for the 2 wells on-site. PIC stated he is getting this completed this week. (per the Georgia Department of Public Health and Georgia Department of Natural Resources memorandum of understanding.) A nonpublic water system serving less than twenty-five trailer spaces or guestrooms, must be constructed, maintained, and operated according to applicable state and local codes and procedures, as amended

1 - adequate, approved, permitted, protected potable water supply; no cross connection or back siphonage

Regulation: 511-6-2-.07(3) - back siphonage

5 ptsCorrected: NoRepeat: No

Observed no backflow prevention on sites 3, 7, and 8. The water supply shall be protected so as to preclude the possibility of back siphonage. Below grade stop and wastes cocks or hose bibs shall not be used

34 - grounds, walkways, porches and hallways maintained; drives provide unobstructed width and proper spacing; graded to drain; trailer spaces marked clearly, areas clean and maintained in good repair

3 ptsCorrected: NoRepeat: No

Observed trailer space Site 1 without a distinct identification mark. Each trailer space shall be distinctly marked. 511-6-2-.18 Grounds (5)

22 - approved leak proof containers covered, in proper location, clean, and maintained; collection adequate

Regulation: 511-6-2-.12(2) - garbage and refuse containers

2 ptsCorrected: NoRepeat: No

Observed provided garbage dumpster missing its drain plug. All outside refuse or garbage storage containers shall be constructed of durable metal or other approved types of materials, which do not leak and do not absorb liquids and shall be provided with tight-fitting lids or covers and shall be kept covered when stored. Each container shall be located within 100 feet of dwelling units or trailer spaces or in a location approved by the Health Authority and shall be cleaned at such frequency as to prevent a nuisance or odor

20 - sewers and drains maintained, connections capped

Regulation: 511-6-2-.09(2) - watertight connection

1 ptsCorrected: NoRepeat: No

Site 1 sewer hoses were damaged and patched with duct tape. Each independent trailer space shall be provided with a sewer connection not less than three inches in diameter. The design of these sewer connections shall be such that a watertight junction will be made with the trailer outlet. Each sewer connection shall be so constructed that it can be closed and when not in use shall be capped to prevent escape of odors

21 - watertight sewer connections with trailer outlets; properly sized

Regulation: 511-6-2-.09(2) - watertight connection

1 ptsCorrected: NoRepeat: No

Site 1 sewer hoses were damaged and patched with duct tape. Each independent trailer space shall be provided with a sewer connection not less than three inches in diameter. The design of these sewer connections shall be such that a watertight junction will be made with the trailer outlet. Each sewer connection shall be so constructed that it can be closed and when not in use shall be capped to prevent escape of odors