Tifton, Tift County

Quality Inn Tifton Spa

1104 KING RD TIFTON, GA 31793

Pool
Latest score
79
Feb 20, 2026
City
Tifton
County
Tift
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Feb 20, 2026

Routine

Score: 794 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine disinfectant at 0ppm. CTM: EHS will return for re-inspection once chemicals are brought into compliance. Do not reopen until re-inspection is completed.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

Observed pH above 8. CTM: EHS will return to re-inspect spa once levels are brought into compliance.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed no functioning flow meter. CTM: Before re-inspection and opening, repair/replace flow meter.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

511-3-5.06(1)(y) Observed deck not clear of trash/debris. CTM: Clean all trash and debris from pool/spa deck prior to reopening pool. Spa to remain closed due to other items not in compliance.

Nov 20, 2025

Routine

Score: 852 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine disinfectant at 0ppm. CTM: EHS will return for re-inspection once chemicals are brought into compliance. Do not reopen until re-inspection is completed.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH above 8. CTM: EHS will return to re-inspect spa once levels are brought into compliance.

Apr 17, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Mar 7, 2025

Routine

Score: 754 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not operational. POC: Do not plan to reopen pool until repaired.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

511-3-5.17(1)(c) Observed combined chlorines measured at 0.6ppm POC: perform breakpoint chlorination to remediate

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(1) - (1) all swimming pools and spas covered by this chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equ

5 ptsCorrected: NoRepeat: Yes

Observed incomplete log sheets since Dec 2024 (see photos in paper file)

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed chemical readings not being taken twice daily while spa is in operation.

Aug 14, 2024

Routine

Score: 803 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine disinfectant at 0ppm. CTM: EHS will return for re-inspection once chemicals are brought into compliance. Do not reopen until re-inspection is completed.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

Observed pH above 8. CTM: EHS will return to re-inspect spa once levels are brought into compliance.

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(1) - (1) all swimming pools and spas covered by this chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equ

5 ptsCorrected: YesRepeat: No

Observed spa log not being completed. COS: EHS reviewed with PIC - trained on testing and other items on log - filled out today's log.

Apr 19, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jan 18, 2024

Routine

Score: 951 violation

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(9) - (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal

5 ptsCorrected: NoRepeat: No

Observed pool logs not being completed.

Jul 28, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.