LOGANVILLE, Walton County

Richmond Place II-(LARGE POOL)

1060 RICHMOND PLACE WAY LOGANVILLE, GA 30052

Pool
Latest score
100
May 1, 2026
City
LOGANVILLE
County
Walton
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 1, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 28, 2025

Re-inspection

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: Yes

Universal International "NO DIVING" symbol not provided on deck surface

Jul 25, 2025

Re-inspection

Score: 832 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: Yes

Emergency phones does not work

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: Yes

Universal International "NO DIVING" symbol not provided ion deck surface

Jul 22, 2025

Routine

Score: 832 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Emergency phone does not work

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Universal international "NO DIVING" symbol not provided on deck surface

Apr 29, 2025

Permit/Opening

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Universal International NO DIVING symbol not provided on deck surface

Jul 23, 2024

Routine

Score: 912 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(11) - (11) if the water test results are not in compliance with dph rule 511-3-5-.17, the operator shall close the pool, record findings, and make the necessary adjustments to the water chemistry to comply with the chapter. the chemicals used and amounts s

5 ptsCorrected: NoRepeat: No

Water test results not in compliance/no daily documentation. Chemical log not checked twice daily

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Universal international symbols for "NO DIVING" not permanently visible at the edge of the deck beside depth markers

May 2, 2024

Permit/Opening

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Universal international symbols for "NO DIVING" not permanently visible at the edge of the deck beside depth markers

Aug 1, 2023

Routine

Score: 903 violations

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Skimmer weirs missing out of multiple skimmers around pool

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Daily chemical check not being logged/checked twice daily as required

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Pol deck surface in disrepair on left side of pool middle way at 5 ft depth marker