Adairsville, Bartow County

Quality Inn

107 PRINCETON BLVD ADAIRSVILLE, GA 30103

Pool
Latest score
100
May 18, 2026
City
Adairsville
County
Bartow
Inspections
8

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 18, 2026

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 13, 2026

Permit/Opening

Score: 842 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: NoRepeat: No

Observed shepherds hook not securely attached to pole. CA: Body hook shall be securely attached to 12' pole.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Observed no directional arrows to identify water flow. CA: All piping shall be marked with directional arrows as necessary to determine flow direction.

Jul 10, 2025

Re-inspection

Score: 951 violation

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine level at 2.25ppm. CA: CPO should adjust levels to ensure combined chlorine level does not exceed 0.4ppm to keep disinfectant effective

Jul 8, 2025

Routine

Score: 852 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed chlorine level at 0.68ppm. CA: Informed PIC that levels must range from 2.0-10.0ppm. Adjust upward and call for reinspection prior to allowing patrons in the pool

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed PH at 6.9. CA: Informed PIC that PH must range from 7.2 -7.8. Adjust pH upward and call for reinspection before allowing patrons in the pool

May 27, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 23, 2025

Permit/Opening

Score: 852 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed gate that did not self latch or close without force. CA: informed CPO gate must be repaired.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not operational. Informed CPO pool must remain closed until phone is operational and EH confirms operation.

May 23, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

May 22, 2024

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone not operational. Informed PIC and CPO pool must remain closed until phone is operational and EH confirms operation