Macon, Bibb County

Pointe Grand Macon

5560 RIVERSIDE DR MACON, GA 31210

Pool
Latest score
98
Jul 3, 2025
City
Macon
County
Bibb
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jul 3, 2025

Re-inspection

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

EHS observed incorrect lifeguard signage.

Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”.

PIC to correct signage.

Jul 2, 2025

Routine

Score: 803 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

EHS observed FCl at .18.

Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0.

PIC to adjust.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

EHS observed pH at 6.9.

pH is to be maintained between 7.4-7.6.

PIC to adjust to appropriate level.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

EHS flowmeter at 31 gpm. For a 30k gallon pool, a 6 hr. turnover rate would require 125 gpm.

PIC to adjust to appropriate flow.

Apr 24, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Apr 16, 2025

Permit/Opening

Score: 803 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed low chlorine levels. (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0. Facility is aware of the low levels and made adjustments prior to the start of the inspection.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.09(9)(a) - (a) the pump vacuum gauge shall be installed as close to the suction side of the pump as possible while still maintaining an accurate reading.

4 ptsCorrected: NoRepeat: No

Observed vacuum gauge not working/filled with water. a) The pump vacuum gauge shall be installed as close to the suction side of the pump as possible while still maintaining an accurate reading. EHS informed PIC of the need to replace the vacuum gauge.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed low alkalinity levels. EHS informed PIC of the need to balance the water chemistry.

Apr 4, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 28, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.