Macon, Bibb County

Rivoli Run Apartments

200 CHARTER LN MACON, GA 31210

Pool
Latest score
77
Jun 2, 2026
City
Macon
County
Bibb
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 2, 2026

Permit/Opening

Score: 774 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

EHS observed emergency phone not connecting to dispatch.

An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times.

PIC to repair phone.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH observed at 7.0. Low.

pH to be maintained at 7.2 (7.4-7.6) 7.8

PIC to adjust.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

EHS observed that float line at depth break missing.

A rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of seven feet or less.

PIC to replace.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

EHS observed missing skimmers on two of three skimmers.

Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

PIC to replace.

May 23, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Aug 1, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 15, 2024

Permit/Opening

Score: 7312 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed both gated entrance with doors that don't self-close/latch unless opened to maximum width. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. EHS informed PIC of the need to assure the gates self-close/latch at any opened width.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed low chlorine levels. (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0 EHS informed PIC of the need to balance the water chemistry.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter barely bobbing. (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. EHS informed PIC of the need to clean it out to see if it helps with the flow.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

Observed skimmers that weren't skimming although PIC stated they were on. EHS informed PIC of the need to determine what's going on with the skimmers.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:

2 ptsCorrected: NoRepeat: No

Observed pool Risk signage had small lettering. c) The same sign in subsection (b) above or an additional sign will state under the heading “Pool Risks” the following items in clearly legible letters at least one inch high. EHS had informed facility during the prior year of the need to purchase signage with bigger (1 inch) letters.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

Observed the Risk of drowning, supervise children closely signage with small lettering. (b) Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”. EHS had informed facility during previous year that the lettering had to be 4 inches minimum.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed NO DIVING stencil in 4 inch letters need on both sides of the pool at the 3 FT depth marker. (a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers. EHS informed PIC of the need to place NO DIVING at the 3FT depth markers on both sides of the pool.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

Observed no 911 signage/facility address & contact information posted on the emergency phone. EHS informed PIC of the need to post the noted information.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed signage of the bather load and pool hours needed in 4 inch letters; no signage posted. (c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. EHS informed PIC of the need to post the noted information.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed pool walls and bottom with discoloration. EHS was unsure if the paint/plaster had been eaten away or if it was discolored due to dirt or algae. EHS informed PIC of the need to determine the issue. If the issue is the paint/plaster has peeled away, the facility will need to re-paint/plaster the pool.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed the facility needing to re-caulk around the tile on the pool wall where it is peeling away. EHS informed PIC of the need to address the issue.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed low chemical levels for the following: alkalinity and cyanuric acid. EHS informed PIC of the need to balance the water chemistry.