Jun 11, 2026
Routine
Score: 972 violations
16B - plumbing installed; proper backflow devices
Regulation: 511-6-1.06(2)(d) - backflow prevention, air gap (p)
2 ptsCorrected: YesRepeat: No
EHS observed:
-3C sink at bar, 3C sink in main kitchen without sufficient clearance between sewage input and sink output.
An air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch (25 mm).
PIC hacksawed pipe to provide clearance.
15A - food and nonfood-contact surfaces cleanable, properly designed, constructed, and used
Regulation: 511-6-1.05(6)(q)1&3 - good repair & calibration (c)
1 ptsCorrected: NoRepeat: No
EHS observes:
- cold mixing valve to 3C nonfunctional.
Equipment must be maintained in state of repair.
PIC to repair valve.