Macon, Bibb County

METHODIST HOME (Seasonal)

304 PIERCE AVE MACON, GA 31204

Pool
Latest score
84
Jul 23, 2024
City
Macon
County
Bibb
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jul 23, 2024

Routine

Score: 843 violations

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

EHS observed the free chlorine levels at 1.67. PIC informed EHS that pool was maintained on yesterday. Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

Informed PIC to have chemicals adjusted. This must be corrected by 07/25/24

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.

15 ptsCorrected: NoRepeat: No

EHS observed pH reading above the maximum reading. The pH reading is 8.1 b) During operation, the pH is less than the minimum or more than the maximum levels allowed in DPH Rule 511-3-5-.l7. Informed PIC to have pH chemicals adjusted. This must be corrected by 07/25/24

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

EHS observed all other chemicals, alkalinity, calcium hardness, cyanuric acid, pH, (see water quality and gauge readings) all below the minimum requirements.

Informed PIC to adjust chemicals. This must be corrected by 7/25/24

Jun 17, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 7, 2024

Permit/Opening

Score: 786 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

EHS observed pool unable to self close was hanging low and sticking on concrete. Violation: pedestrian gates shall be self-closing and self-latching. CA: Ensure self-closing mechanism is functioning.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

EHS observed free chlorine at 0.45 ppm. Violation: pools not using cyanuric acid or a stabilized chlorine product shall have a disinfectant level 0f 1.0 ppm. CA: ensure chlorine salt generators are working correctly.

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

EHS observed the pump on right side of pool (smaller filter) not functioning properly pressure gauge was bouncing from 0-10 psi and flow meter was bouncing from 40-100 gpm. Violation: pump shall be capable of maintaining proper turnover rate and working.

13 - float line in position

Regulation: 511-3-5-.18(2) - (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of

4 ptsCorrected: NoRepeat: No

EHS observed float line not in line with tile line on bottom of pool marking where 5' mark is. Violation: (2) Rope and Float Line. A rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of seven feet or less. CA: verify float line is at transition point.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

EHS observed the words "No Diving" but there was no symbol for "No Diving". Violation: Universal International Symbol of "No Diving" shall be placed on the pull deck next to depth markers. CA: place symbol on pool deck.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

EHS observed piping marked with arrows but not labeled. Violation: equipment shall be labeled with use and what pool or feature it serves. CA: label filters or pumps with what they are connected to.