Macon, Bibb County

LA QUINTA INN & SUITES - POOL

4615 CHAMBERS RD MACON, GA 31206

Pool
Latest score
74
Mar 9, 2026
City
Macon
County
Bibb
Inspections
2

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 9, 2026

Permit/Opening

Score: 746 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed no 911 sign posted nearby.

511-3-5-.18(10)(c ) - (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

Corrective action discussed with PIC to have either a 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue.

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed pool Free Chlorine at 0.36 after testing.

.17(1)(a)(b) - Proper disinfectant level (1) Disinfectant Levels (a) Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0

Corrective action: Discussed with Assistant manager to have CPO balance chemicals.

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

Observed combined chlorine levels above 0.4.

Corrective action: Discussed to have pool chemicals balanced.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Observed no weirs no any of the skimmers within pool.

511-3-5-.11(3)(d) - (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Corrective action: Discussed to have weirs installed and check if skimmers a properly pulling water.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Observed most piping within pool room missing directional arrow markers.

511-3-5-.08(6) - (6) All piping shall be marked with directional arrows as necessary to determine flow direction. All piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves. (6) All piping shall be marked with directional arrows as necessary to determine flow direction. All piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

Corrective action: Discussed to have markers added.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed low alkalinity levels.

Corrective action: Informed staff about having water chemicals balanced.

Aug 19, 2025

Permit/Opening

Score: 827 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed flow meter was not working. (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. EHS informed the PIC of the need for the CPO to check/replace the flow meter.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

EHS is unsure is the skimmers are operating as no pull was observed in the skimmer basket. CPO is to ensure the skimmers are operating effectively.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Observed pressure gauge on the filter was not working. a) A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location. CPO will need to change out the pressure gauge.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

Observed entrance ladder with broken tread and another tread with a damaged grip. EHS informed the PIC of the need to repair the ladder.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed facility without the No Diving symbol at each depth marker on the pool deck. (a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above. EHS informed the PIC of the need to install the NO DIVING symbols at each depth marker on the pool deck.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed facility's need to install a drinking fountain on the pool deck that attaches to a fresh water line. EHS informed the PIC of the need to install a drinking fountain.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Observed low alkalinity levels. CPO is to balance the water chemistry.