5235 BOWMAN RD MACON, GA 31210
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Observed the side entry gate near the restrooms not self-latching at every opening. (h) Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate. EHS informed the maintenance guy of the need to fix the latching mechanism.
Regulation: .17((1)(c) - proper disinfectant level
Observed chlorine levels exceeding the max; unable to obtain a numerical reading. (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0. EHS informed the CPO of the need to balance the water chemistry; he shocked the pool prior to EHS arrival as he observed the levels were extremely low.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed PH levels at 8.5. (2) Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180 ppm as CaC03 100-120 halogen compounds with low pH Calcium hardness, ppm, CaCo3 150 200-400 to balance water 1000. EHS informed the CPO of the need to balance the water chemistry; he added muriatic acid on-site.
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
EHS was unable to test the combined chlorine levels as the free chlorine levels were too high. (1) Disinfectant Levels (a) Free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. EHS informed the CPO of the need to balance the water chemistry.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not working; guage was stuck. (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications. EHS informed the CPO of the need to fix the flow meter.
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Observed bather load (4 inch lettering) and pool hours not posted at the entrance gates.(c) A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. EHS informed the Maintenance guy of the need to post the information at the entrance gate.
Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Observed NO DIVING symbol present, however it was covering the NO DIVING wording. (a) The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above. EHS informed the CPO and maintenance of the need to shift the symbols to the right of the words NO DIVING.
Regulation: 511-3-5-.09(2) - (2) strainer or screen. with all pressure filter systems, a cleanable strainer or screen shall be provided upstream of the circulation pumps to remove solids and debris such as hair and lint.
Observed the pump strainer basket in need of cleaning. (2) Strainer or Screen. With all pressure filter systems, a cleanable strainer or screen shall be provided upstream of the circulation pumps to remove solids and debris such as hair and lint. EHS will notify the CPO of the need to clean the strainer basket.
Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
Observed piping needing to be labeled with the feature that it services. (6) All piping shall be marked with directional arrows as necessary to determine flow direction. All piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves. EHS informed the CPO of the need to label the piping that services the main drain and skimmers.
Permit/Opening
Routine
Observed skimmer baskets with excessive debri inside. EHS informed PIC of the need to clean the skimmer baskets.