Mar 10, 2026
Permit/Opening
100 RIVER OAKS DR RICHMOND HILL, GA 31324
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Observed tile that is a tripping hazard. CA: Repair or replace tile so that it is flush to the deck and no longer a tripping hazard.
Permit/Opening
Regulation: 511-3-5-.06(1)(l) - (l) open joints or gaps larger than three-sixteenths inch wide or with vertical elevations exceeding 1/4 inches shall be rectified using appropriate fillers. construction joints where pool coping meets the decks shall be watertight and shall not allo
Observed tile that is a tripping hazard. CA: Repair or replace tile so that it is flush to the deck and no longer a tripping hazard.
Permit/Opening
Routine
Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Observed that when phone was tested the 911 operator could not provide locations address. CA Ensure 911 operators have address for pool.
Regulation: .17(1)(a)(b) - proper disinfectant level
Observed a Free Chlorine level above 10 PPM. CA lower fCHL to a level between 10-2 PPM.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed a PH level of 8.1 during inspection. CA lower PH to a level between 7.2 and 7.8.
Routine
Permit/Opening
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Observed flow meter not working and registering a level of zero. C.A. Make sure flow meter is withing appropriate level.