Kingsland, Camden County

Microtel Inn & Suites

1325 E KING AVE KINGSLAND, GA 31548

Pool
Latest score
95
Mar 9, 2026
City
Kingsland
County
Camden
Inspections
7

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 9, 2026

Permit/Opening

Score: 952 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 145 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, until CYA is below 90 ppm.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, there are several areas chipping in the marcite in the floor of the pool. The pool needs resurfacing.

Jul 14, 2025

Re-inspection

Score: 952 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the cyanuric acid (CYA) level registered at 119 (CYA must be 90 ppm or less). CPO will continue draining and adding fresh water at intervals, to ensure that CYA is 90 ppm or less.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: Yes

At time of inspection, the marcite is severely chipped and eroded. There are several spots with concrete exposed underneath the marcite. Marcite chips are filling up the pump basket over time. The pool must be resurfaced.

Jul 10, 2025

Permit/Opening

Score: 767 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter is not functioning. Fix or replace the flow meter.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

At time of inspection, the deck tile bearing "FT" is cracked and loose on the far side of the pool. All depth marker tiles shall be intact and secured to the deck. Replace tile.

20 - return inlets maintained

Regulation: 511-3-5-.10(1)(c )1.ii. - (ii) the fitting shall not constitute a hazard to the user.

4 ptsCorrected: NoRepeat: No

At time of inspection, all but one of the covers for the return inlets are missing. Replace covers to improve circulation and to not pose a hazard to swimmers.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 122 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, to lower CYA.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

At time of inspection, the pressure gauge is completely clouded. Replace pressure gauge.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

At time of inspection, the "NO LIFEGUARD ON DUTY..." sign is missing. Replace the "NO LIFEGUARD ON DUTY" sign.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

At time of inspection, the marcite is severely chipped and eroded. There are several spots with concrete exposed underneath the marcite. Marcite chips are filling up the pump basket over time. The pool must be resurfaced.

Nov 1, 2024

Re-inspection

Score: 942 violations

36 - daily recordkeeping: water testing and self inspection performed

Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

5 ptsCorrected: NoRepeat: No

Daily inspection not being done.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Pipes not clearly marked. Label piping with direction and equipment served.

Oct 31, 2024

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone is not operational. PIC contacted the owner to troubleshoot the phone. PIC placed a lock on the pool gate.

May 30, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 27, 2023

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter is not working, at time of inspection.