Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
At time of inspection, the flow rate is slightly low (should be at least 280 GPM), thereby causing the turnover rate to be less than adequate. The CPO thinks a sand change in the filters may be needed; he will address.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
At time of inspection, the cyanuric acid level is exceeding the maximum (observed at 101 ppm, must be 90 ppm or less). CPO will drain some water and add some fresh water.
Permit/Opening
Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
At time of inspection, observed combined chlorine above maximum (CC must be 0.4 ppm or less). CPO will drain some water and add fresh water.
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
At time of inspection, observed cyanuric acid level above maximum (CYA must be 90 ppm or less). CPO will drain some water and add fresh water.