St. Marys, Camden County

Sugarmill Plantation Club Pool

2400 SUGARMILL BLVD SAINT MARYS, GA 31558

Pool
Latest score
100
Mar 16, 2026
City
St. Marys
County
Camden
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Mar 16, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Sep 23, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

Apr 7, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 16, 2024

Routine

Score: 912 violations

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow rate is slightly low (should be at least 280 GPM), thereby causing the turnover rate to be less than adequate. The CPO thinks a sand change in the filters may be needed; he will address.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid level is exceeding the maximum (observed at 101 ppm, must be 90 ppm or less). CPO will drain some water and add some fresh water.

Apr 30, 2024

Permit/Opening

Score: 912 violations

18 - combined chlorine level 0.4 ppm or less

Regulation: 511-3-5-.17(1) - (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.

5 ptsCorrected: NoRepeat: No

At time of inspection, observed combined chlorine above maximum (CC must be 0.4 ppm or less). CPO will drain some water and add fresh water.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, observed cyanuric acid level above maximum (CYA must be 90 ppm or less). CPO will drain some water and add fresh water.